Wolf Customer Care 800.222.7820
Installation Requirements
Install the hood 36" (914) to 84" (2134) from the bottom of the
hood to the countertop.
The hood requires a 600 CFM internal or in-line blower
assembly, or a 600 CFM or 1200 CFM remote blower
assembly, available through an authorized Wolf dealer.
Consult a qualied HVAC professional for specic installa-
tion and ducting applications.
SPECIFICATIONS
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration below. Allow a minimum 12"
(305) wire
(Romex) for connection. A separate circuit servicing only
this appliance is required.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Rating plate location
RATING PLATE
(ABOVE FILTERS)
E
36"
(914) TO 84" (2134) BOTTOM EDGE TO COUNTERTOP
Electrical location