Wolf IS15/S Spécifications Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
3
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
Save these Installation
Instructions for the local inspector’s use.
Please read the entire Installation
I
nstructions prior to installation.
This installation must be completed by a
qualified technician.
Installer:
please retain these instructions
for local inspector’s reference, then leave
them with the homeowner.
Homeowner:
please read and keep
these instructions for future reference and
be sure to read the entire Use & Care
Information prior to use.
IMPORTANT NOTE:
This appliance must be
installed in accordance with National Electri-
cal Codes, as well as all state, municipal and
local codes. The correct voltage, frequency
and amperage must be supplied to the appli-
ance from a dedicated, grounded circuit
which is protected by a properly sized circuit
breaker or time delay fuse. The proper
voltage, frequency, and amperage ratings are
listed on the product rating plate.
Record the model and serial numbers before
installing the steamer module. Both numbers
are listed on the product rating plate located
on the underside of the module. Refer to the
illustration below.
BEFORE YOU START
IMPORTANT NOTE:
Installation and service
must be performed by a qualified installer or
s
ervice agency. Warranty service must be
performed by a Wolf authorized service center.
Installation of the steamer module must
meet the minimum clearance requirements
f
or safe operation. Refer to Site Preparation
on page 4.
Electrical installation must be adequate
and in compliance with all local codes and
ordinances. Electrical ground is required,
refer to Electrical Requirements on page 8.
The steamer module must be installed with
a drain connection and access to the drain
through the base cabinet. Refer to Drain
Connection on page 6.
If the steamer module is to be used with
any combination of additional cooktop units
or modules, refer to Multiple Cooktop
Installation on page 6.
IMPORTANT NOTE:
A ventilation hood is
recommended (but not required) for use with
the Wolf electric steamer module.
This module is intended for indoor use.
WOLF STEAMER MODULE
M
odel IS15/S
Rating plate location
Model Number
IS15/S
Serial Number
Location of rating
plate under module
Vue de la page 2