Troubleshooting
IMPORTANT NOTE: I
f the pro hood liner does not operate
properly, follow these troubleshooting steps:
Verify electrical power is supplied to the appliance.
Verify all packaging material has been removed.
If the appliance does not operate properly, contact
Wolf factory certified service. Do not attempt to repair.
Wolf is not responsible for service required to correct a
faulty installation.
Complete the Installation
FILTER INSTALLATION
To install filters, press upward then rotate bottom outward.
The filter vanes should be placed perpendicular to the
front of the hood. Refer to the illustration below. To aide in
removal, remove center filter first. Gloves should be worn
when handling filters.
LIGHT BULB INSTALLATION
A suction-cup-style light bulb changer is provided with
pro hood liners. Use the changer to push the bulb into the
receptacle and rotate counterclockwise one-quarter turn.
Refer to the illustration below.
FILTER
SIDE VIEW
SPRING
LOWER
CHANNEL
Filter installation. Light bulb installation.
LIGHT BULB
CHANGER
Pro Hood Liner Installation 10