Pro Wall Hood Specifications 7
wolfappliance.com/specs
Installation Options
HORIZONTAL DISCHARGE
Pro low-profile wall hoods have an adjustable discharge.
Pro 24"
(610) and 27" (686) deep wall hoods have a vertical
discharge. A horizontal discharge kit is available through
your authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com.
RECIRCULATING INSTALLATION
Pro wall hoods, 30" (762) and 36" (914) wide, with an
internal blower (600 CFM or less), can be used in a non-
ducted application with a recirculating filter. In this installa-
tion, kitchen air is purified through filters and returned as
clean air into the room. A recirculation kit available through
your authorized Wolf dealer is required. For local dealer
information, visit the find a showroom section of our
website, wolfappliance.com.
DUCT COVER
Optional stainless steel duct covers, in multiple heights,
are available through your authorized Wolf dealer. Duct
covers must be attached to ventilation hood prior to hood
installation. For local dealer information, visit the find a
showroom section of our website, wolfappliance.com.
BACKSPLASH
Optional stainless steel backsplashes, in widths to match
all pro wall hoods, are available through your authorized
Wolf dealer. Backsplash must be installed prior to hood
installation. For local dealer information, visit the find a
showroom section of our website, wolfappliance.com.
Electrical Requirements
W
olf pro ventilation hoods require a separate, grounded
120 V AC, 60 Hz power supply. The service should have its
own 15 amp circuit breaker. Locate the electrical supply
within the shaded area shown in the installation illustration
on the previous page.
In-line and remote blowers require Romex
®
(not provided)
from the blower to the ventilation hood.
IMPORTANT NOTE: You must follow all National Electrical
Code regulations. In addition, be aware of local codes and
ordinances when installing your service.
Risk of electrical shock. This hood must be properly
grounded. Electrical service for the hood must be
installed by a qualified electrician in accordance with
all applicable national and local electrical codes.