NOTE: In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39083 (3/03)
Model SCB-25-CH-18
Super Charbroiler with Oven
ACCESSORIES
➤➤ Extra oven rack.
INSTALLATION REQUIREMENTS:
1. Gas pressure regulators sized for this unit is included.
Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.
2. Gas lines connecting to appliance must be
3
⁄4" or larger. If
flexible connectors are used, the inside diameter must be
the same as the
3
⁄4" iron pipe.
3. An adequate ventilation system is required for commer-
cial cooking equipment. Information may be obtained
by writing to the National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02269, www.NFPA.org.
When writing, refer to NFPA No. 96.
4. These units are manufactured for installation in accor-
dance with ANSZ223.1A (latest edition), National Fuel
Gas Code. Copies may be obtained from The American
Gas Association, 400 N Capitol St. NW, Washington, DC
20001, www.AGA.org.
5. For installation in non-combustible locations only. 3" rear
and 0" side clearance required.
6. For proper combustion, install equipment on adjustable legs
or casters provided with unit. On curb or platform, allow
3
1
⁄2" overhang (see diagram). Leveling bolts are required for
curb installation. Specify when ordering.
Commentaires sur ces manuels