13
Hood Installation—In-Line/Remote Blower
WIRING CONNECTIONS
WARNING
Before making electrical connections, make sure the
electrical power is turned off at the service panel.
Home Supply:
1 Remove the knockout above the home supply junction
box, then insert the home electrical supply (Romex) into
the electrical box. Refer to the illustration below.
2 Secure the electrical supply to the electrical box with a
UL or C/UL approved connector (not provided).
3 Connect the green or bare ground wire to the green
grounding screw. Use appropriate wire connectors (not
provided) to connect white to white and black to black.
4 Place all wiring connections inside the electrical box and
then install the cover. Verify all wires are secure and not
pinched between the cover and electrical box.
In-Line/Remote Supply:
1 Remove the knockout above the in-line/remote blower
junction box, then insert the blower electrical supply
(Romex) into the electrical box.
2 Secure the electrical supply to the electrical box with a
UL or C/UL approved connector (not provided).
3 Connect the green or bare ground wire to the green
grounding screw. Use appropriate wire connectors (not
provided) to connect white to white and black to black.
4 Place all wiring connections inside the electrical box and
then install the cover. Verify all wires are secure and not
pinched between the cover and electrical box.
5 Insert the plug from the control board housing into the
receptacle on the side of the junction box.