WOLF GAS COOKTOPS
Planning Information
GAS SUPPLY
A gas supply line of
3
/4" (19) rigid pipe must be provided
to the cooktop. If local codes permit, a certied, 3'
(.9 m)
long,
1
/2" (13) or
3
/4" (19) ID exible metal appliance con-
nector is recommended to connect the units
1
/2" NPT male
inlet to the gas supply line.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
in altitude without adjustment and LP gas cooktops
will function up to 8,600'
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)